In addition to the generally applicable information provided in the information sheets on fire protection, you will also find the “Fire protection registration” form in the online Exhibition Configurator. This form must be submitted for stand constructions, systems, equipment, installations or activities that must be reported or require approval and/or authorisation.
As a general rule, the use of materials that are easily ignited, form burning droplets, release toxic gases or produce large amounts of smoke or soot, for example most thermoplastic plastics, including polystyrene (expanded polystyrene), is not permitted under any circumstances at exhibition stands.
Decorative and ornamental materials (such as banners, flags, roll-up banners, etc.) must be classified as at least flame-resistant (Class B1), without burning droplets and, in accordance with DIN 4102-1, with limited smoke development or, in accordance with EN 13501-1, as at least Class C (C -s2, d0).
A general building-control appraisal certificate from a recognised testing, certification and monitoring association regarding the building material class of the decorative materials used must be kept available (cf. >>> Exhibition Configurator >> Fact Sheets > “Certified Testing Laboratories for Material Fire Testing”).
The appraisal certificate must be submitted in German (official language). Appraisal certificates in English will only be accepted in exceptional cases.
You are required to guarantee visual contact between the internal space and the corridor, aisle or atrium at all times. The doors or windows of the middle row must therefore remain free of any stickers or branding material. Where applicable, layouts must be approved by the City Fire Department. If these rules are not observed, stickers and printed material will be removed at your expense. Solutions that comply with fire protection regulations can be booked via the online Exhibition Configurator (for example under “Signage Atrium Rooms”).
You are not permitted to display any decorative material such as banners, flags, roll-up banners, decorations or items of furniture outside your room/stand.
Please ensure that the marked routes remain unobstructed throughout the installation and assembly period. You can find a corresponding plan under >>> Exhibition Configurator >> Fact Sheets > “Factsheet Fire Protection Set Up Time”.
Emergency exits are marked and must be kept free at all times with no exceptions. This rule applies to the entire width of the emergency exits without exception. The emergency exit signs must remain clearly visible at all times and are not permitted to be covered. Where applicable, additional signs showing the way to the emergency exit should be added to the stand area.
Sprinkler systems must be certified by the technical inspection centre VdS and be mounted with metal cable ties or Spannfix bungee cords that are flame-resistant in accordance with DIN EN 13501-1: B-s1, d0 or classified as Class B1 in accordance with DIN 4102-1.
Fire loads (packaging material, wooden crates, pallets etc.) are not permitted to be stored at the stand or in the room. For storage services, please contact the forwarding company Schenker, which can be found in the delivery zone behind the halls (Spedition Schenker at the MOC: +49 89 3241125).
You are permitted to keep a daily supply of advertising material at your stand / in your room.
You can view the “Technical Guidelines” of the MOC Event Center Messe München and the above-mentioned documents at any time in our online Exhibition Configurator: Exhibition Configurator
If you have any questions, please feel free to contact us – we will be happy to help you further.
Best regards,
Your Team
HIGH END SOCIETY Service GmbH
Vorm Eichholz 2g | 42119 Wuppertal | Germany
Telefon: +49 202 702022
info@highendsociety.de